KB0 is intended to be connected to circuits of rated voltage not exceeding 690V,and rated current from 0.16A to 100A, 50Hz (60Hz) AC, available for making, carryingand breaking currents under normal conditions including specified operatingoverload conditions, and also available for making, carrying for a specified timeand breaking currents under specified abnormal conditions (such as short-circuitcurrent).KB0 is of modular design, associated and coordinated with the functions of traditionalcircuit breaker, fuse, contactor, over-load relay, starter, and disconnector,intended to provide both protective and control functions for remotely or localmanually controlled circuits, having front indications, signal alarm and time-currentcharacteristics, and also available for control and protection of motorsand distribution circuits by using optional modules or accessories.KB0 is designed to be operated either by automatic control or by manual control,able to have functions of remote control and direct manual control. KB0 can beinstalled in a predetermined cabinet to be formed as a power terminal box, whichis available for distribution protection and control of the outside and remote independentload.
For adopting modularization structure to realize integration and inner harmony coordination control and protection on single structure mode, it owns various function and advantages of circuit breaker,
For adopting modularization structure to realize integration and inner harmony coordination control&protection on single structure mode, it owns various function and advantages of circuit breaker,cont
Double-speed KB0D:KB0 is used as a main switch and composed of appropriate contactors and electricalinterlocker to be formed as KB0D double-speed controller, intended for controland protection of doub
Double-speed KB0D:KB0 is used as a main switch and composed of appropriate contactors and electricalinterlocker to be formed as KB0D double-speed controller, intended for controland protection of doub
Triple-speed KB0D3:KB0 is used as a main switch and composed of appropriate contactors and electrical interlocker to be formed as KB0D3 triple-speed controller, intended for control and protection of
Triple-speed KB0D3:KB0 is used as a main switch and composed of appropriate contactors and electrical interlocker to be formed as KB0D3 triple-speed controller, intended for control and protection of
A CPS is designed with both control and protective functions capable of being usedto replace fuse, contactor, relay, starter and disconnecter. KB0 is a first generationCPS, which has filled in the gap
A CPS is designed with both control and protective functions capable of being usedto replace fuse, contactor, relay, starter and disconnecter. KB0 is a first generationCPS, which has filled in the gap
KB0 for isolation:Isolation type KB0 is available for isolating of distribution circuit and the powerof motor circuit. It is suitable for isolation either for main circuit or forcontrol circuit. Its o