Address: No.1168 Daohang Road,Development Zone,Economic Development Zone, Rui'an, Zhejiang, China (Mainland) Zip: 325200
Phone: +86-577-65156767
Mini Circuit Breaker
Confirming to IEC60898, IEC60947-2Against overload and short circuitRated current: 0.5,1,2,3,4,6,10,13,16,20,25,32,40,50,63ARated voltage: 1 Pole 230/400V AC 50/60Hz2,3,4 Pole 400V AC 50/60HzAmbient temp: -5°C to +40°C pursuant to IEC60898Breaking capacity: 10kACharacteristic: thermal operating limit: (1.13-1.45)xinMagnetic operating: B: (3-5)xinC: (5-10)xinD: (10-20)xinNumber of poles: 1P,1P+N,2P, 3P+N and 4PType of trip: Thermal/magnetic releaseType of terminal: Lug typeTerminal capacity: 16mm flexible or 25mm rigid up to 25A ratings25mm flexible or 35mm rigid for 32A to 63A ratingsInstallation: Mounting on 35mm DIN railWidth: 17.8mm per pole
Confirming to IEC60898, IEC60947-2Against overload and short circuitRated current: 0.5,1,2,3,4,6,10,13,16,20,25,32,40,50,63ARated voltage: 1 Pole 230/400V AC 50/60Hz2,3,4 Pole 400V AC 50/60HzAmbient t
Confirming to IEC60898, IEC60947-2Against overload and short circuitRated current: 0.5,1,2,3,4,6,10,13,16,20,25,32,40,50,63ARated voltage: 1 Pole 230/400V AC 50/60Hz2,3,4 Pole 400V AC 50/60HzAmbient t
Confirming to IEC60898, IEC60947-2Against overload and short circuitRated current: 0.5,1,2,3,4,6,10,13,16,20,25,32,40,50,63ARated voltage: 1 Pole 230/400V AC 50/60Hz2,3,4 Pole 400V AC 50/60HzAmbient t
Confirming to IEC60898, IEC60947-2Against overload and short circuitRated current: 0.5,1,2,3,4,6,10,13,16,20,25,32,40,50,63ARated voltage: 1 Pole 230/400V AC 50/60Hz2,3,4 Pole 400V AC 50/60HzAmbient t
MGV2 series motor protection circuit breakers are mainly used for the overload and short circuit protection of the motor in AC 50/60Hz, up to 660V, 0.1-80A power circuit, as a full-voltage starter to
MGV2 series motor protection circuit breakers are mainly used for the overload and short circuit protection of the motor in AC 50/60Hz, up to 660V, 0.1-80A power circuit, as a full-voltage starter to
This moulded case circuit breaker is suitable for circuit AC 50Hz/60Hz, rated voltageup to AC 660V, Rated operating current to 800A. It is for distribute energyof electricity and infrequent making and
MGB-CS,CP,SS series Moulded Case Circuit Breaker is a kind of economic breaker, hasthe features as following, such as steady and reliable property, reasonable structure,beautiful style, small volume,
MGB-CS,CP,SS series Moulded Case Circuit Breaker is a kind of economic breaker, hasthe features as following, such as steady and reliable property, reasonable structure,beautiful style, small volume,