Address: No.43-1,2,Jiaoyu Road,Liushi Town, Yueqing, Zhejiang, China (Mainland)
Phone: +86-577-62777268
XFIN Residual Current Device
The Residual Current Device XFIN is in conformity with the standard of IEC61008. It can cut off the fault circuit immediately on the occasion of shock hazard of earth leakage of trunk line. Thus it is suitable to avoid the shock hazard and fire caused by earth leakage.NFIN RCD is mainly suitable for use in varieties of plants and enterprise, building construction, commerce, guesthouses and families. It can be used in circuits of 1 phase 230V and 3 phases 415V 50/60Hz.SPECIFICATION:Type:XFIN-2PNumber of poles:2PRated Current:16,20,25,40,63,80,100ARated residual operating current:30,100,300,500mARated residual non-operation current(mA):≤0.5mARated Voltage: 230V ACResidual current off-time;≤0.1sShort Circuit Capacity:3000AEndurance:≥4000Terminal protection:IP20
The Residual Current Device XFIN is in conformity with the standard of IEC61008. It can cut off the fault circuit immediately on the occasion of shock hazard of earth leakage of trunk line. Thus it is
C Residual Current Device C is in conformity with the standard of IEC61008. It can cut off the fault circuit immediately on the occasion of shock hazard of earth leakage of trunk line. Thus it is suit
MCB DZ47 (C45) series circuit breaker is used in lighting distribution system or motor distribution system for protecting overload and short-circuits in the system. The product is novel in structure,
XFN6 series circuit breaker belongs to the advanced level of the nineties in the world instead of the old generation of DZ47.They have protective functions as shortage and overloading, and are used in
DPN leakage protective breaker, protective breaker is used in the single phase residence circuit of AC 50Hz/60Hz, rated voltage 230V, used as electron shock protection. It can protect civil electron c
DZ47LE earth leakage circuit breaker is used for the protection against electrical leakage in the circuit of 50Hz or 60Hz, rated voltage single-phase 230V, 3-phase 415V, rated current up to 60A. When
The design on the base of the current-limiting device increases the capability of circuit breaking, with a max. of 7.5KA (AC 220V standard)The super-miniature and light product leaves the installation
XFBKN series circuit breaker is used in the lighting distribution system or motor distribution system for protection overload and short-circuit in the system. The product is neoteric in structure, lig
The product is used to protect line conductor, overload and short circuit of small size motors. It is mainly for protection of circuits with AC 220V and 50Hz/60Hz, and for unfrequented conversion unde