Address: 555 Baoqian Road, Jiading, Shanghai, China (Mainland) Zip: 201808
Phone: +86-21-39977076
Mining Flame-Proof Vacuum Feeder Switch
1) Model: KBZ-630/1140(660), BKD9-400/1140(660), BKD-350/1140(660)2) It can be used in coal mines full of explosive gas mixture (methane and coal dust) to start the big capacity motor infrequently in the three-phase of AC power-supply of 50Hz, rated voltage 660V or 1,140V, rated current is less than 630A as the feeder switch, distribution switch and sub-switch for movable transformer station3) The inner is equipped with a vacuum contactor. It has an integrated protector with the functions of overload, short circuit, fault-phase and leakage
1) Name: explosion-proof corrosion proof control station2) Model: BZA80503) Ex-mark: II2GExedIICT64) PCEC no.: PCEC CE0212745) Applicable in Zone 1, Zone 2, Zone 21 and Zone 226) 3 type enclosures of
1) Name: explosion-proof corrosion proof plug and socket2) Model: BCZ80503) Ex-mark: II2GExedIICT64) PCEC no.: PCEC CE0211445) Applicable in Zone 1, Zone 2, Zone 21 and Zone 226) A, B structure; 16A,
1) Name: explosion-proof corrosion proof terminal box2) Model: BXJ80503) Ex-mark: II2GExeIIT64) PTB no.: PTB06ATEX 10135) Applicable in Zone 1, Zone 2, Zone 21, Zone 226) Made of engineering plastic,
1) Name: explosion-proof distribution panel2) Model: BXM(D)51, BQD, BXQ513) Ex-mark: II2GExdeIIBT6, II2GExdeIICT6, II2GExdIIBT64) PTB no.: PTB03ATEX 10785) Applicable in Zone 1, Zone 2, Zone 21 and Zo
1) Name: explosion-proof pipe fittings2) Model: DQM, BGJ, BHC, BNG, BAG3) Ex-mark: II2GExeIIT6, II2GExdIIC, II2GExdIIB4) LCIE no.: LCIE04ATEX 1087X5) Applicable in Zone 1, Zone 2, Zone 21 and Zone 226