Russian German French    |    help
   Add to favorite    Favorite products
   
Description
Electronic Components & Parts /  Electro-Adjusting Components & Materials /  Cable Accessories / 
Producer information
Company:
Xingle Group Co., Ltd.
 
Address:
Back Street Industrial Zone, Liushi Town, Yueqing, Zhejiang, China (Mainland) Zip: 325604
 
Phone:
+86-577-62772822

Power Cables with Aluminum Conductor XLPE Insulation PE Sheath


Product Name: Power Cables with Aluminum Conductor XLPE Insulation PE SheathModel Number: YJLVPlace of Origin: ChinaFeatures:1) Rated voltage UO/U: 0.6/1, 1.8/3, 3.6, 6/6, 6/10, 8.7/10, 8.7/15, 21/35, 26/35kV2) The highest allowed operating temp. of conductor for long-term working is 90°C3) In short-circuit the highest temp. for conductor is no more than 250°C4) DC resistance of the conductor complies with the stimulations of GB/T39565) The insulating environment temp. should be no lower than 0°C, otherwiseit should be preheated6) The min. bending radius should be no smaller than 15 times of cable outerdiameter7) The cable is laid without drop limit8) Lower smoke & low halogen flame-retardant cable could endure firing test inbundle as GB/T18380.3smoke density in firing complies with stimulation GB/T17651.19) HCL content of gas separated out in firing should be no more than 100mg/g10) Lower smoke & halogen-free flame-retardant cable could endure firing test inbundle as GB/T18380.3smoke density in firing complies with stimulation GB/T17651.211) PH value of solution water of gas separated out should be less than 4.3 andelectric conductivity rate should be no more than 10∫s /mm12) The delivery length depends on agreement with length error no more than 0.1%

Add to BasketAdd to Basket Web addressWeb address



Other goods of this manufacturer :
0.6/1KV PVC Insulation Power Cable
 0.6/1KV PVC Insulation Power Cable ( 0.6/1KV PVC Insulation Power Cable)
Product Name: 0.6/1KV PVC Insulation Power CablePlace of Origin: ChinaFeatures:1) The max long-term operating temperature of cable conductor is no more than70°C2) Environment temperature in laying
0.6/1KV PVC Insulation Power Cable
 0.6/1KV PVC Insulation Power Cable ( 0.6/1KV PVC Insulation Power Cable)
Features:1) The max long-term operating temperature of cable conductor is no more than70°C2) Environment temperature in laying the cable should not be lower than 0°C,otherwise it should be p
10KV or 35KV Aerial Insulated Cable
 10KV or 35KV Aerial Insulated Cable ( 10KV or 35KV Aerial Insulated Cable)
Features:1) The max. long-term operating temperature of cable conductor:a) XLPE insulation :90°Cb) HDPE insulated 150°C2) Cable installed in air, ambient temp. is 40°C3) Intensity of solar
10KV or 35KV Aerial Insulated Cable
 10KV or 35KV Aerial Insulated Cable ( 10KV or 35KV Aerial Insulated Cable)
Product Name: 10KV or 35KV Aerial Insulated CablePlace of Origin: ChinaFeatures:1) The max. long-term operating temperature of cable conductor:a) XLPE insulation :90°Cb) HDPE insulated 150°C2)
1KV or Lower Aerial Insulated Cable
 1KV or Lower Aerial Insulated Cable ( 1KV or Lower Aerial Insulated Cable)
Features:1) The max long-term operating temperature of cable conductor:a) XLPE insulation: 90°Cb) PVC insulation 70°Cc) PE insulation: 70°C2) The laying temperature of the cable should not
1KV or Lower Aerial Insulated Cable
 1KV or Lower Aerial Insulated Cable ( 1KV or Lower Aerial Insulated Cable)
Product Name: 1KV or Lower Aerial Insulated CablePlace of Origin: ChinaFeatures:1) The max long-term operating temperature of cable conductor:a) XLPE insulation: 90°Cb) PVC insulation 70°Cc) P
35KV or Lower XPEL Insulation Power Cable
 35KV or Lower XPEL Insulation Power Cable ( 35KV or Lower XPEL Insulation Power Cable)
Features:1) Rated voltage UO/U: 0.6/1kV, 1.8/3kV, 3.6kV, 6/6kV, 6/10kV, 8.7/10kV,8.7/15kV, 21/35kV, 26/35kV2) DC resistance of the conductor complies with the stimulations of GB/T39563) The cable is l
35KV or Lower XPEL Insulation Power Cable
 35KV or Lower XPEL Insulation Power Cable ( 35KV or Lower XPEL Insulation Power Cable)
Product Name: 35KV or Lower XPEL Insulation Power CablePlace of Origin: ChinaFeatures:1) Rated voltage UO/U: 0.6/1kV, 1.8/3kV, 3.6kV, 6/6kV, 6/10kV, 8.7/10kV,8.7/15kV, 21/35kV, 26/35kV2) DC resistance
Aluminium Core Power Cable
 Aluminium Core Power Cable ( Aluminium Core Power Cable)
Features:1) Rated voltage: 1,500V2) Max. operating voltage: 1,800V3) Allowed bending radius:4) Flexible cable should be no smaller than 8 times of cable diameter5) Fixture cable should be no smaller t

Likewise in category "Cable Accessories":
 Rigid Type Stranding Machine
Rigid Typ...
 Cage Type Stranding Machine
Cage Type...
 Extrusion Line
Extrusion...
 Cable Clips
Cable Cli...
 Cable Reel
Cable Ree...
 Steel Casting (Ⅲ)
Steel Cas...
 
Copyright © 2006 - 2011 Asia.ru
 
eHouseHolding.com