Адрес: Huayangnian,huahaoyuan community,Jitou Town, Wuhou District
Телефон: +86-28-85218395
.
Intrinsic safety explosion barrier is an explosion-proof device with single channel, Zener-diode DC circuit that enables interactive electric signaling without short circuit while controlling energy transmission in order to prevent ignition in explosive atmosphere. 1.Applicable to Zone 0. 2.A-class ground is not necessary since the input and output are insulated each other. 3.When serially connected to a transmission circuit, the barrier protects the circuit and components in hazardous area from being affected by a serious accident in the non-hazardous area. 4.Despite in the hazardous location, conventional wiring is available. 5.Intrinsical proof of operational signal is figured out easily and at lower cost. 6.SAF100-5 safety barrier employ crimping terminal wiring method. 7.As SAF100-5 safety barrier has protection circuit, it will be not broken if you wired in the wrong polarity. 8.LED indicates the condition of the input and output Model code SAF100-5 Explosion-proof construction Intrinsic safety construction(ExiaⅡC) Rated voltage DC24V±10% Maximum voltage of a intrinsic safety circuit DC29.4V Max. allowable voltage DC25.95V Maximum current of a intrinsic safety circuit 93.8mA Electric power of a intrinsic safety circuit 0.689W Ambient temp. -20~50℃ Basic circuit figure Does not need A-class ground. Operating condition 1.Place the valve in non-hazardous area. 2.Perform single grounding using type A ground. 3. Parts and connections cannot be changed. 4. Use with specified solenoid valves. 5. Allowable inductance for external connection: 2mH / Capacitance: 0.05 μF
Intrinsic safety explosion barrier is an explosion-proof device with single channel, shunt-diode DC circuit that enables interactive electric signaling without short circuit while controlling energy t
Employing poppet structure for both main valve and pilot valve, this product has achieved optimal resistance to drains and dusts. Incorporated exhaust pressure protection system ensures reliable opera
Suitable for single-acting actuators and diaphragm valves. Two types (NC, NO) are available. The valve incorporates plastic cassette valve, low power consumption solenoid, and DIN connector Compact in
Sub-plate type solenoid valve focusing safety in operation and easy maintenance. Employing sizes complying with ISO and JIS standards, this valve is suitable for multiple applications With standardize
Direct piping type 5-port solenoid valve that is a mainstay of Magster III series. With basic concepts of compact size, large flow, and low power consumption, this high-performance valve has been deve