English Russe Französische    |    Hilfe
   Zu Favoriten     Dem Warenkorb hinzugefügte Favoriten
   
Beschreibung der Ware
Medizinisch & Arzneimittel /  Medizinische Ausrüstung /  Chirurgie-Ausrüstung / 
Informationen über den produzenten
Firma:
Hubei Kangda Medical Equipment Co.,Ltd
 
Adresse:
No.230,Hanyang Ave,Hanyang district
 
Telefon:
+86-27-84702718

.

APPLICATION SCOPE -Apply to kinds of removal surgical operation (for human body and animals) - Skin beauty therapy (ephelides ,wart and mole removal) -Dermatology therapy (adenoma sebaceum, condyloma acuminate, flat wart, plantar wart, veTTrruca vulgaris) -Dental surgery (gingival hyperplasia, pericoronitis ) - Otolaryngology surgery (Chronic hypertrophic rhinitis, Nasal polyps & nasal cavity angioneoplasm) -Anus surgery (Internal hemorrhoid, External hemorrhoid, intestines) -Gynecological surgery (Cervical Erosion, Na-cyst, cervival polyp,Nymp FEATURES Electrocautery unit is a kind of electrosurgical instrument, it is used to cut the body lesions and replace the traditional scalpels. The effective electrode tip of it will produce high pressure & frequency current to heat, separate and coagulate the lesions when in contact with the patient body, and finally reach the goal of cutting and coagulation. This instrument is indicated for cutting and coagulation surgery in general surgical, orthopedics, gynecologic, urological, anus intestines and so on. Resection, hemostasis, vaporization, coagulation 4in1 functions helps rapid removal of lesions to promote healing. Flexible adjustment of treatment styles contain long fire and short fire, be adjusted to meet different clinical needs. Operate easily, safe and reliable, compact design to be portable. Foot switch is more convenient and safe for operation. Apply to the human body and animal surgery. TECHNICAL SPECIFICATIONS Working mode: long fire, short fire Operation mode: Switch of long fire / short fire Switch mode: Foot switch Power supply: AC. 220V±22V,50MHz±1MHz Operating frequency: 1.3MHz±10% Output : 12W±20% (on the condition of non-inductive load of 500Ω) Continuous working time: ≥4h Rated input power: 300VA Security type: classⅡtype BF Size: 350mm(length)×273mm(width)×125mm(height) Net weight: 4.5Kg Gross weight: 5.5Kg
In den WarenkorbIn den Warenkorb Internetauftritt des HerstellersInternetauftritt des Herstellers




Andere Waren dieses Produzenten :
 ()
APPLICATION SCOPE -remove skin wart , Skin rejuvenation, resurfacing - Wrinkle removal & skin tighten - Acne and acne scar removal -Smooth burnt scars and surgery scars, dermabrasion etc. - Remo

 
Copyright © 2006 - 2011 Asia.ru
 
eHouseHolding.com