Industrieausrüstung /  Energieausrüstung /  Andere Energieausrüstung / 
Informationen über den produzenten
Firma:
Ningbo Tianan Group Co.,Ltd
 
Adresse:
NO.1118 Tianan Road, Xiangshan, China
 
Telefon:
+86-574-65705207

.

Techinical Parameter:H.V. unit40.5kVKYN10-40.5JYN1-40.5ZN23-35ZN12-35LN2-35(Z)Rated voltagekV40.5Rated currentA1250-1600Rated short-circuit breaking currentkV20-31.5Rated short-circuit making current(crest)A50-80On-load startingNAL36NALF36Rated currentA630Rated short-time withstand currentkA/s25/2L.V. unit12kVXGN56-12XGN2-12KZN1-12KYN1-12ZN28A-12ZN28B-12VD4VT2-12VT1-12Rated voltagekV12Rated currentA630-3150Rated short-circuit breaking current(r.m.s)kA16-50Rated short-circuit making current(crest)kA40-125HXGN11-12(F)HXGN26-12(F)On-load startingFN16-12FN26-12FN26-12RRated currentA630Rated short-time withstand currentkA/s20/3,25/20.4kVGGDGCTGCSDW15ME, M, FDZ20CM, H, S seriesRated current of circuit breakerA70-3900Breaking capability(400V)kA28-80Transformer unitSC9,S9,SZ9 transformerRated voltagekV40.5Rated capabilitykVA400-20000RatiokV / kV35/10,35/6.3,35/0.4
In den WarenkorbIn den Warenkorb Internetauftritt des HerstellersInternetauftritt des Herstellers




Andere Waren dieses Produzenten :
 ()
Rated voltagekV40.5Lightning impulse withstand voltage(peak value)Phase to earth & phase to phasekV185Isolating distancekV2151minpower frequency withstand voltagePhase to earth, phase to phasekV95
 ()
Technical parameter:ItemUnitDataRated voltage (Max working voltage)kV12Rated insulation level1min power frequency withstand voltagekV42Lightningimpulse withstandvoltagekV75Rated frequencyHz50Main busb
 ()
H.V. unitRated voltagekV12Rated current of main bus-barA630Rated short-time withstand currentkA/s25/2Rated crest withstand currentkA63Rated short-time making currentkA63Breaking current of fuserkA31.5
 ()
product features 1 .product standards gb1094.1 ~ 2-1996 gb1094.3 ,5-1985 gb/t6451-1995 iec76 2. low loss - optimization of electromagnetic calculations, using combined technology of electrical shieldi
 ()
Main transformer Capacity (MVA)5,7.5,10,15,20,25,31.5Rating of HV sideSwitchgear (kV)33,66,77,110,132,138Rated current (A)1250,2000Rated short-circuit breaking current (kA)25,31.5,40Rating of LV sideS
 ()
Technical data item specification unit parameter 1 rated voltage kv 40.5 2 rated frequency hz 50 3 rated current a 630 4 rated short-time withstand current ka/s 20/2 5 rated peak withstand current ka
 ()
1.Wide-spreading application : Furnace transformer can be used widely for various kinds of furnace. 2.Withstanding short-circuit capability : Operation under the various severe situations3.Low noise :
 ()
Main technical parameter of GISNameUnitParameterRated voltagekV40.524Rated currentA630 1250 2000 2500Rated frequencyHz50/60Rated power frequency withstand voltage (1min)phase to phase,phase to earthkV
 ()
1.Cable channel2.Material: PP,PE, Nylon, PET3.Size: required by customer4.Customized designs are welcome.Optional Information- Payment : T/T- Delivery : Sea or air- Origin : China- Packaging : Carton-