6MT Dual Cylinder Assembled Hose Steam Boiler


Specifications:1) Actual evaporation: 6MT/h 2) Pressure: 1.25MPa3) Saturated steam temperature: 194oC4) Water supply temperature: 60oC5) Tested thermal efficiency: 81.12%6) Outer size (L x W x H): 8.0 x 3.6 x 6.15m 7) Fuel category: soft coal IIThe boiler is with a dual cylinder longitudinal structure and natural cycle methodsconsisting of the upper components with the dominant main parts. The lower componentsare primarily the combustion equipment. The two main parts can be instantlyinstalled and manufactured.The boiler housing is with dense water exhaust cooling wall around the hearth. Partitionis mounted at the back of the hearth in front of the convection check andforms the combustion ash room. Convection check is mounted at the back of thecombustion ash room. The smoke flows into the first and the second checks throughthe combustion ash room and exhausts into the chimney through the coal saver anddust catcher.Structure: 1) Upper and lower cylinder diameter: φ 900mm 2) Cylinder central distance: 2,300mm 3) Left-right cabinet: φ219mm4) Level central distance: 2,340mm5) Hearth water cooling wall pitch: 53mm6) Convection check distance: 90 x 120mm7) The side wall is connected by 4 descending tubes leaded from the upper cylinder8) There are 4 φ108 x 4.5 descending tubes at each side of the lower cylinder connected with the concentration cabinets9) The boiler check and the water cooling wall are welded and connected with the upper and lower cylindersCombustion equipment: 1) Light chain-grate stoker2) Width: 1,600mm3) Effective area: 7.78m24) Six independent wind storage cabinets5) Dual-side air inlet ash door6) Brick boiler arc7) Front water cooling arc and level angle are 30o8) Outlet height: 1,013mm9) Back arc outlet height: 764mm10) Front-back arc coverage rates are 21% and 46.5%11) The block wall is mounted at the upper outlet of the front arc to increase the combustion room temperature and smoke flowDesign features: 1) After extensive selection, the vertical hose boiler is easily defined and symmetrical facilitating manufacture and maintenance. It is with compact size and low metallic consumption, great water capacity and large convection heat transfer coefficient 2) To reduce the boiler wall weight, the side water cooling wall pitch is densely structured and gets rid of the fire-bricks. Burial boiler wall increases the air-tightness 3) Back arc and outlet block wall of the hearth are brick structured to increase the temperature in addition to expanding the fuel application 4) Manhole is not installed in the combustion ash room. Smoke flow speed may be increased appropriately, because the sole is mounted to exhaust the ash to the lower grate 5) Front wall water cooling wall and descending tube are mounted to increase the rigidity of the upper part 6) An aisle is reserved at the two sides of the convection check to reduce dead corners and to facilitate maintenance 7) A hidden door is reserved at the back of the left side of the second convection check. If necessary, the aisle can be reached through the hidden door 8) Compressed shell, stylish design9) Step-less motor and shift of the grates are necessary for the automatic combustion 10) Equipped with multifunctional meter control panel; the inspection display meter, the water supply automatic control panel, and the coal combustion control panel are for manipulating rotating speed on the operation table 11) Thermal data determination: subject to the determination of National Industrial Boiler Product Quality Inspection Center, the heated surface of the boiler is with reasonable configuration and large overload capacity of more than 10%. The average efficiency is 81.12%

Add to BasketAdd to Basket Web addressWeb address



Other goods of this manufacturer :
8MT Dual Cylinder Assembled Steam Boiler
 8MT Dual Cylinder Assembled Steam Boiler ( 8MT Dual Cylinder Assembled Steam Boiler)
Specifications:1) Model: SZL8-1.25-AII coal steam boiler2) Rated evaporation: 8MT/h3) Pressure: 1.25MPa4) Saturated steam temperature: 194oC5) Water supply temperature: 60oC6) Tested thermal efficienc
Boiler (WNS)
 Boiler (WNS) ( Boiler (WNS))
WNS series automatic fuel (gas) boilers are with instant installation and horizontal inner combustion boiler with three strokes, wet backs and fire tubes. The main press components include boiler shel
Bulk Hot Water Boiler
 Bulk Hot Water Boiler ( Bulk Hot Water Boiler)
Technical parameters:1) Specification: SZL29-1.6 / 130 / 70-AII bulk water pipe hot water boiler2) Rated heat supplying: 29mW3) Water discharge pressure: 1.6MPa4) Returned water temperature: 70oC5) Wa
Bulk Hot Water Boiler
 Bulk Hot Water Boiler ( Bulk Hot Water Boiler)
DHL29-1.6 / 130 / 70-AII bulk hot water boiler is a single-drum horizontal chain-grate boiler, in Π-shaped structure and installed indoor. This boiler can be used as a large centralized steam boile
Coal Chain-Grate Power Station Boiler
 Coal Chain-Grate Power Station Boiler ( Coal Chain-Grate Power Station Boiler)
Technical parameters:1) Rated evaporation: 35MT/h2) Rated vapor pressure: 3.82MPa3) Rated vapor temperature: 450oC4) Vapor working pressure in the boiler: 4.21MPa5) Feeding water temperature: 150oC6)
Cycle Fluidized-Bed Boiler
 Cycle Fluidized-Bed Boiler ( Cycle Fluidized-Bed Boiler)
Technical parameters:1) Rated evaporation (BMCR): 35MT/h2) Rated vapor pressure: 3.82MPa3) Rated vapor temperature: 450oC4) Major feeding water temperature: 150oC5) Major feeding water pressure: 5.61M
Double-Drum Bulk Steam Boiler
 Double-Drum Bulk Steam Boiler ( Double-Drum Bulk Steam Boiler)
Technical parameters:1) Specification: SHL35-1.6-AII bulk water pipe steam boiler2) Rated evaporation: 35MT/h3) Rated working pressure: 1.6MPa4) Steam temperature: saturation 204oC5) Feeding water tem
Garbage Incinerator
 Garbage Incinerator ( Garbage Incinerator)
According to the kinds, components, heat, states, moisture content and other factors of the wastes, choose the most suitable incinerator to ensure burning stability and fullness and to meet the treatm
Steam (Hot Water) Boiler
 Steam (Hot Water) Boiler ( Steam (Hot Water) Boiler)
Features:1) Main part: dual cylinder hose boiler2) Natural cycle code3) Top and bottom cylinders, hose system, wall heat preservation layerand exterior steel structure are assembled in the factory4) Q

Likewise in category "Boilers":
 Single-Drum Package Coal Fired Steam Boiler
Single-Dr...
 Double-Drum Bulk Superheated Steam Boiler
Double-Dr...